PR-2000 Product Support |
NOTE: It is suggested that only qualified technicians use these repair guidelines, ignoring to do so could result in a void of your warranty. This information is to be used as a guideline only, and cannot be gauranteed to solve your specific repair issue. |
|
1. The PR-2000 shows no display screen & the phase lamps DO NOT illuminate. |
|
- Check that the wall & cabinet breakers are on. - Check house power level (all phases) at panel, breaker and outlet. |
2. The PR-2000 shows no display screen & the phase lamps DO illuminate. |
|
- Check that the display screen has power & the phase lamps are on. - Check accidental press of gun trigger. |
3. The PR-2000 makes a weak weld. |
|
- Check gun setup: squeeze pressure, shank & arm, tip condition & alignment. |
4. Soft-start delay relay not functioning and no weld from either gun. |
|
|
5. Double-sided gun does not weld, single sided does. |
|
|
6. Weld error message issued & no weld from either gun. |
|
- Confirm supply voltage to welder. Bridge in high current section generates 300VDC for IGBTs.
|
7. Pop sound reported in cabinet, no weld either gun & soft start relay ok. |
|
- Inspect systems to locate pop source following input voltage check.
|
8. Temperature error message issued or no air cooling. |
|
- Check sensor Display readout (100 C =failure / 30+/-ok) Also see ambient / outdoor temperature.
|
9. Cabinet circuit breaker trips. |
|
- Check breaker and high current wiring. |
10. Facility (wall) breaker trips. |
|
- Check outlet & plug. |
|