Pro Pull Product Support |
NOTE: It is suggested that only qualified technicians use these repair guidelines, ignoring to do so could result in a void of your warranty. This information is to be used as a guideline only, and cannot be gauranteed to solve your specific repair issue. |
|
1. No Display Screen & No Phase Lamps (Wall and Cabinet Breakers are ON) |
|
- Check house power level (all phases) at panel, breaker and outlet. |
2. No Display Text or No Navigation (Display Screen has power & Phase Lamps are ON) |
|
Check accidental press of gun trigger. |
3. Makes Poor Nugget (Guns weld) |
|
Check gun setup (squeeze pressure, shank & arm choice, tip condition & alignment). |
4. Soft-Start Delay Relay not functioning (No weld either gun) |
|
|
5. No Squeeze Gun stroke / No Weld (Dent-Pull Gun does weld) |
|
|
6. Weld Condition Error Message Issued (No weld at guns.) / Poor voltage or burned part. |
|
Confirm supply voltage to welder. Bridge in high current section generates 300VDC for IGBTs.
|
7. Pop Sound Reported in Cabinet ( No Weld either gun & Soft Start Relay OK) |
|
Inspect systems to locate pop source following input voltage check.
|
8. Temperature Error Message Issued or No Air Cooling (Could involve either or both guns.) |
|
Check sensor Display readout (100 C =failure / 30+/-ok) Also see ambient / outdoor temperature.
|
9. Cabinet Circuit Breaker Trips |
|
Check breaker and high current wiring. (See Items #6 & 7.) |
10. Facility (wall) ) Breaker Trips |
|
Check outlet & plug. (Usually a problem outside or near cabinet wall.) (See Items #6 & 7) |
|